Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0924-05463
Parcel: 126180190

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SOLAR v.1

Permit Number - TC-RES-0924-05463
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/23/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/01/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-0924-05463 (4065 E CAMINO DE LA COLINA TUCSON, AZ 85711)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC).

Structural:
1. For wind uplift use 115 mph in 3sec gust, Table R301.2(1). https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/building-code/2018_-_irc_amendments.pdf
2. For pre-manufactured/site-constructed ground mounted systems, the Foundation and Structual design must be engineered/designed, sealed and signed by an Arizona Registered engineer, to support the weight of the system and to resist the wind uplift, R106.1, R324.4.1.2.

Electrical:
3. Provide a Grounding Electrode System at the detached structure per NEC 690.47.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
10/23/2024 Site Engineering REQUIRES RESUBMIT TC-RES-0924-05463
4065 E CAMINO DE LA COLINA

Comments for Site Engineering are as follows:
1. This project is within a regulated floodplain, Paseo Grande Wash, and requires a Floodplain Use Permit (FUP.)

Please start a new FUP at our permit application web page:
https://tdc-online.tucsonaz.gov/#/home

NOTE: A cost estimate of materials and labor from your contractor in the form of a pdf attachment will be required to complete the FUP application. Please have separate lines for cost of materials, and cost of labor. Thank you.
10/10/2024 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: Wyatt Berger
Lead Planner

PROJECT: TC-RES-0924-05463
4065 East Camino De La Colina – R-1
Detached solar carport (1st Review)

TRANSMITTAL DATE: October 10, 2024

The site is in the R-1 zone (UDC 4.7.8). A single-family dwelling is a permitted use in the R-1 zone, subject to use-specific standards 4.9.7.B.5-.9.

COMMENTS:

1. Provide a site plan that meets the residential plot plan requirements found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf. At a minimum, the required site plan shall meet the following requirements:
a. Be drawn at an engineering scale (i.e., 1” = 20’)
b. Show the square footage of the lot, the existing dwelling, all existing and proposed accessory structures, and the total under roof area
c. Provide a lot coverage calculation (the area of the site occupied by buildings, storage areas, and driveways)
d. Show the square footage of the proposed structure
e. Indicate the maximum structure height
f. Include dimensions from the centerline of Camino De La Colina to the curb location, and from the curb location to the front street property line. Per sheet two of paving plan I-589, the distance between the centerline of Camino De La Colina and the back of curb is 15 feet, and the distance between the back of curb and the front street property line is 15 feet: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-589
g. Include legal description “PALMOAR LOT 6 BLK 2.”

2. The property line dimensions are labeled incorrectly on the site plan. According to the Palomar Addition plat, the site is 100 feet wide and approximately 129.6 feet deep: https://maps-and-records.tucsonaz.gov/subdivisions/details/983.

3. Per UDC 6.4.5.C.1.a, for a single-family and duplex development, the minimum required front street perimeter yard is 20 feet as measured from the street property line. However, detached shade structures or carports may project up to ten feet into the required 20-foot setback. As the proposed detached carport does not appear to meet the minimum required 10-foot setback as measured from the front street property line, a Design Development Option (DDO) is required to reduce the above setback.

The DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo_for_setback_and_height_udc.pdf. Submit a completed DDO application under existing permit number TC-RES-0924-05463. Contact Georgia.Pennington@tucsonaz.gov or Mark.Castro@tucsonaz.gov if you have questions about the DDO process.

4. Interior perimeter yard setbacks are based on a measurement from the design grade elevation to the highest point of the post supporting the roof structure (UDC 6.4.5.B.2). Per UDC Table 6.3-2.A, the required side perimeter yard setback is six feet or 2/3 the height of the post supporting the roof structure, whichever is greater, measured from the west property line.

As the minimum required setback is not being met, a neighbor waiver signed by the owners of 4049 East Camino De La Colina can be used to reduce the side perimeter yard setback. The waiver must be pasted directly onto the site plan and shall include the following language:

My name is ________ and I am the owner of property located at ________. I have reviewed the site plan and have no objection to the structure being constructed __ feet from the west property line as depicted on the site plan.

Signature: ________

Date: ________

If the neighbor waiver cannot be obtained, the side perimeter yard setback can also be reduced through the DDO process.

If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised plan set as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf.
09/22/2024 PDSD Application Completeness Express REVIEW COMPLETED