Permit Number: TC-RES-0924-05429
Parcel: 116262350

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-0924-05429
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/05/2024 Site Engineering NOT REQUIRED
11/05/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/15/2024 Residential Building REQUIRES RESUBMIT TC-RES-0924-05429
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections.

Place each page numbered sheet into a single plan set.

Provide a response letter on separate file from the updated construction plan set.

Provide a clear and concise construction plan set. Sample drawings are available for understanding details. Sample plans at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits

SITE PLAN:

1. Show the location of the electrical service panel, R106.1.1.

PLANS:

1. Show a floor plan labeling the proposed function of proposed room and identify any openings between the dwelling and enclosed carport, R106.1.1.

SECTIONS - DETAILS:

1. Provide a wall section detail with (#4 rebar) reinforced 12” x 12” reinforced foundations for anchoring exterior framed (insulated) walls with pressure treated sills including ½” anchor bolts with 7” embedment, R403.1.6.
2. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground (R317.1 item 5). The weep screed may extend with a minimum clearance 4” above grade or 2” above paved areas, R703.7.2.1.
3. Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation, R806. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38.

MECHANICAL PLAN:

1. Show the HVAC system size for the addition in accordance with M1401.3, M1601.1 if proposing living space.

ELECTRICAL PLAN:

1. Show the location of each outlet on the Electrical Plan of the proposed room, E3404.12. Identify each light, switch and receptacle as (E) existing or with a circuit number if proposed.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
11/01/2024 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Ramiro Olivarez
Planner, Zoning Review Section

PROJECT: TC-RES-0924-05429
2501 W Calle Puebla TUCSON, AZ 85745 – R-1 Zoning
Carport Enclosure (1st Review)

TRANSMITTAL DATE: 11/01/2024

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9

COMMENTS: Please resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed.

Provide a residential plot plan that meets the requirements and is designed to include the information as noted on the sample plot plan. See the link below for the information that is required on the plot plan. https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/addition_sample.pdf

1. Comment: Combine the plan set into one PDF document.
2. Comment: Label on the site plan the zone (R-1) and all the adjacent property zones on the site plan. Or show a zoning detail of this properties zone and all adjacent property zones on the site plan. (As noted on the sample plot plan above)
3. Comment: Include the complete Legal Description of this property. (Legal description can be found at the following Pima County Information Link: https://gis.pima.gov/maps/detail.cfm?&parcel=116262350)
4. Comment: A full-floor plan labeling each room of the home shall be included for the next review. (Need to verify the number of total bedrooms in the existing dwelling)
5. Comment: All structures shall be drawn, labeled, and dimensioned on the site plan. Including the detached shed and the wall/fence which aerial views show on the property.
6. Comment: The property dimensions (Lot 233) do not match those found in the Recorded Subdivision Plat Map Book 18, Page 80. Dimension and draw the northeastern property corner radius (25’). Correct the property drawing and all dimensions. https://onbase.pima.gov/publicaccess/DS_NextGen_Single/etc/cq/results.html?cqid=240&OBKey__552_1=18080
7. Comment: Draw, label, and dimension the utility easement (20’) on the eastern portion of the property. Refer to the Recorded Plat Book in the comment above.
8. Comment: Draw, label, and dimension the back of curb to property line and center line of Calle Puebla and Greasewood Rd to the property lines as depicted on the sample plot plan. Draw, label, and dimension the rear alley (16’ wide). (As noted on the sample plot plan above) (Refer to the Recorded Plat Book above for an example.)
9. Comment: Provide the total lot coverage calculations. Per UDC article 6.4.3 lot coverage shall need to include the area of a lot covered by buildings, storage areas, including dimensioned vehicular use areas. Do not include the porch square footage in the total lot coverage calculations. (As noted on the sample plot plan above)
10. Comment: Ensure on the elevation sheet that the height of all proposed exterior walls is measured from design grade (the ground) to the top of the wall. To ensure setbacks are compliant.
11. Comment: Additional comments may be forthcoming on the next review based on the proposed use for the addition and applicable use specific standards.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Provide a complete plan set in the next submittal.

If you have any questions about this transmittal, please contact Ramiro Olivarez Ramiro.Olivarez@tucsonaz.gov
10/09/2024 PDSD Application Completeness Express REVIEW COMPLETED