Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0924-05424
Parcel: 118033570

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SOLAR v.4

Permit Number - TC-RES-0924-05424
Review Name: RESIDENTIAL SOLAR v.4
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/04/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/04/2025 Light Residential Building Review (OIP) REQUIRES RESUBMIT TC-RES-0924-05424 (2060 S SAN JOAQUIN AV TUCSON, AZ 85713)

1. The chosen inverter can only support a maximum grid current of 80A, but your plans show a 200A backfeed breaker to the inverter. Please let me know how you would like to address this issue or provide additional information/spec-sheets to justify the 200A backfeed breaker. See inverter specification sheets under AC Input Data, "Max. Gen/Grid Pass Through Current".
01/16/2025 PDSD Application Completeness Express REVIEW COMPLETED