Permit Number: TC-RES-0924-05409
Parcel: 123030260

Address:
1625 N TREAT AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0924-05409
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/17/2024 Site Engineering NOT REQUIRED
10/04/2024 Site Landscape NOT REQUIRED
10/17/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/24/2024 Residential Building REQUIRES RESUBMIT TC-RES-0924-05409
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections.

Provide a response letter on separate file with the updated construction plan set.

SECTIONS - DETAILS:

1. Clarify if furring and insulated walls are existing or proposed at keynote #3 sheet 5, R106.1.1.
2. Show a minimum 1” ventilation clearance between ceiling insulation and roof sheathing over the wall and eave area when including eave venting, R806.3. This is accomplished w/ baffles. Or show an unvented roof assembly with air-impermeable rigid insulation material of a minimum R-5 value applied correctly to either side of the roof sheathing as part of the total ceiling insulation requirement, R806.5. Note the elevation or provide an insulation detail showing spray foam or rigid foam board and batt layers. Ceiling insulation may be reduced to R-30 when extended over the wall top plate for additions under 500 SF.

PLUMBING PLANS:

1. Show all drainage fixtures with connection to the public sewer system, P2602.1 and with an appropriate vent, P3105.1.
2. Clarify if the pressure and temperature relief valve for the water heater terminates at the exterior 6 inches above grade facing down, P2804.6.1 or into a pan, P2801.6.
3. Show if the building clean-out is existing or relocated, P3005.2.5.

MECHANICAL PLANS:

1. Show the HVAC system size for the addition in accordance with M1401.3, M1601.1.

ELECTRICAL PLANS:

1. Show the Heat pump (mini split) circuit size, E3702.11.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
----------------------
10/09/2024 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Bobby Parsons
Zoning Review Section

PROJECT: TC-RES-0924-05409
1625 N Treat Ave. Tucson, AZ 85716
Rebuild Back Room and Porch (1st Review)

TRANSMITTAL DATE: 10/9/2024

Comment: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

1. Comment: The site plan should be designed to include the information as noted on the sample site plan. Please see https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf for reference.
2. Comment: Please draw, label, and dimension the vehicle use area on your site plan. Also, please remove the porches from the lot coverage calculations as they shouldn’t be included and update the lot calculations to include the vehicle use area.
3. Comment: Please include the density calculations on your site plan. If needed, reference the sample site plan for information about density calculations.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov or (520) 837-4977.
09/18/2024 PDSD Application Completeness Express REVIEW COMPLETED