Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0924-05367
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/21/2024 | Site Engineering | NOT REQUIRED | |||
| 10/04/2024 | Site Landscape | NOT REQUIRED | |||
| 10/21/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/30/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0924-05367 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings. Provide a response letter on separate file with the updated construction plan set. Each dwelling unit with kitchen requires a separate Pima County assigned street address after Zoning approval, R319. Show Pima County assigned unit numbers at each dwelling on the site plan. https://www.pima.gov/1010/Addressing-Frequently-Asked-Questions GENERAL COMMENTS : 1. Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc. 2. All plans submitted for a newly constructed one- or two-family dwelling after July 1, 2009 require a solar photo-voltaic system, or future installation preparation City of Tucson Ordinance #10549 . a. Show a minimum 300 SF clear solar-ready zone on a roof or framing plan, T103.3. Model plans should show four typical south facing roof surfaces. b. Label a double breaker space for future Photo Voltaic on the panel schedule opposite end from the main/supply side, T103.9. Provide a future PV breaker space at the last panel space. 3. All plans submitted for a newly constructed one- or two-family dwelling after June 1, 2010, must provide gray water utilization or preparation, Ordinance #10579/11089 revised July 9, 2013. The ordinance revision now requires a gray drain line discharge from one fixture for a one-story dwelling. Additional gray fixture drains are optional. Show a second clothes washer standpipe plumbed to an exterior wall above grade when feasible, or a bathing fixture drain looped 3’ beyond an exterior wall below grade before connection to the building drain. Show a bathing fixture drain looped 3’ beyond an exterior wall below grade before connection to the building drain when a clothes washer is not located at an exterior wall. Use the appropriate detail at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Water-Energy-Conservation Gray Water Illustrations 4. Show compliance with the Electric Vehicle Supply Equipment Ordinance adopted by the City of Tucson Ordinance #11844 on 6/22/2021. Include a 40 ampere 240-volt dedicated branch circuit with a NEMA 14-50R receptacle for charging an electric vehicle at a proposed parking space. SITE PLAN: 1. Each dwelling unit should have an individual 3-foot clear space (including the roof projections) known as the fire separation distance for reducing fire spread to nearby buildings. Identify the required fire rating at the underside of roof projections while maintaining a minimum of 4 feet between edges. Portions of buildings placed in a fire separation distance require one-hour fire-resistive construction in compliance with IBC Table 721.1(2). PLANS: 1. Notate a cool (white) roof finish (greater than 60 SRI) as required by the ADU provisions. 2. Show a maximum ½” floor elevation changes at a notated accessible route entrance on the floor plan, R106.1.1. Include all threshold conditions for a route from the exterior into the living space. MECHANICAL PLANS: 1. Provide demand calculations in accordance with Manual J standards, M1401.3, M1601.1. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 10/17/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0924-05356 1019 E SILVER ST. – R-2 New SFR (1st Review) TRANSMITTAL DATE: October 17, 2024 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. 1. The lot coverage calculation is not correct. Per UDC Article 6.4.3.C.1.a Roofed areas, porches, open on at least one side are not included in the calculation. 2. Per UDC Article 6.6.3.B.5 For lots less than 6,500 square feet in size, the accessory dwelling unit is limited to 650 square feet of gross floor area . For lots equal to or greater than 6,500 square feet, the accessory dwelling unit is limited to 10% of the lot size, not to exceed 1,000 square feet of gross floor area. Gross floor area (GFA) is defined as the sum of the horizontal areas of all floors of all buildings , including accessory buildings on a lot, measured from the exterior faces of the exterior walls, UDC Article 11.4.8. That said based on sheet A-2, Floor Plan the exterior dimensions are 41’-0 ¼” x 24’-6” = 1,005.5 sq. ft. of GFA. A Board of Adjustment for Variance will need to be submitted and approved to exceed the allowed 1,000 sq. ft. 3. Per UDC Article 6.4.5.c.1 the required street setbacks are shown as measured from street property line but per a discussion with the Zoning Administrator, Elisa Hamblin, the street perimeter yard setbacks should be measured from the existing or future property line as determined by the adopted Major Streets and Routes Plan , whichever is greater. As Glenn is designated on the COT MS&R map as a Collector and the future ½ right-of-way is 32’. Clearly show the future ½ right-of-way line on the plan and provide a side street perimeter yard setback from the proposed ADU to the future right-of-way line. If this setback is less than 10’-0” a Board of Adjustment for Variance will need to be submitted and approved to reduce the setback. The UDC can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. Board of Adjustment application/requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. Contact for the Board of Adjustment is Mark Castro at Mark.Castro@tucsonaz.gov. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 09/19/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |