Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0924-05366
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/15/2024 | Site Engineering | NOT REQUIRED | |||
| 10/04/2024 | Site Landscape | NOT REQUIRED | |||
| 10/15/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/23/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0924-05366 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. Provide a response letter on separate file when submitting the updated construction plan set. Provide a clear and concise construction plan set. See sample drawings for a Porch. Sample plans are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits STRUCTURAL PLANS: 1. Provide a Roof Framing Plan showing the beams sized for supporting live and dead structural loads (Table R602.7(3)) or provide an engineer’s calculation, design, and seal for a performance design when minimum sizes are not code compliant with the IRC, R301.1. 2. Provide a Roof Framing Plan showing the rafters sized for supporting live and dead structural loads (Table R802.4.1(1)) or provide an engineer’s calculation, design, and seal for a performance design when minimum sizes are not code compliant with the IRC, R301.1. SECTIONS - DETAILS: 1 Provide structural roof sheathing and fastening in compliance with Table R602.3 (1). 2 Notate the location and size of ledger anchorage to a load bearing surface, R606.11. 3 Identify all fasteners for wind loading compliance. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended. If you have any questions, please contact: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review |
||
| 10/11/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0924-05366 2079 N CAMINO ALICANTE – R-2 Patio Cover (1st Review) TRANSMITTAL DATE: October 11, 2024 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-2 zone (UDC 4.7.9). A single family residence, attached, is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, 9, & 10. 1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 09/17/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |