Permit Number: TC-RES-0924-05344
Parcel: 136191020

Review Status: Requires Resubmit

Review Details: RESIDENTIAL FENCE/WALL v.1

Permit Number - TC-RES-0924-05344
Review Name: RESIDENTIAL FENCE/WALL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/01/2024 Site Engineering NOT REQUIRED
10/01/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/17/2024 Residential Building REQUIRES RESUBMIT Provide plans showing a foundation and (rebar) fastener size and spacing with wind load calculations sealed by an Arizona engineer for fence structures greater than 7 feet above grade and for block walls placed on retainer walls, R106.1
09/30/2024 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Fernando Garcia
Planning & Development Services Department – Zoning Review Section

PROJECT: TC-RES-0924-05344 – Residential Building – Addition/Alteration
8125 E Victoria Dr, Tucson, AZ 85730
Building Plan Review (1st Review)

TRANSMITTAL DATE: September 30, 2024

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised plans, as noted in the comment below, along with a detailed letter indicating responses to the review comments.

Alert me by email to fernando.garcia2@tucsonaz.gov upon resubmittal for faster review.

1. (Comment) Show swimming pool on next submittal.

2. (Comment) Show dimensioned ramada/gazebo, label, setback from rear property line, and indicate height on next submittal.

3. (Comment) Show setback distance between storage rooms/sheds to the nearest property line. Indicate height for both.

4. (Comment) Indicate full distance of new wall.

5. (Comment) Per UDC Section 6.6.2., height of a fence or wall is measured from design grade. Indicate height of the new block wall using this standard.

6. (Comment) Per UDC Section 6.6.1.I., “the maximum height of a wall or fence within a shall be six feet; however, the wall or fence may be higher than six feet, but no higher than ten feet, if at least 75% of the area above six feet in height is left unobstructed and open through the use of architectural elements, such as arches, columns, or wrought iron.” See UDC 6.6.1., here: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5291

The submitted plans indicate that the block wall will be taller than 6’ in height and completely opaque. In this case, to keep the wall above 6’ feet, you would need to request a Design Development Option (DDO) variance. Please reach out to Georgia Pennington at 520-837-6311 or georgia.pennington@tucsonaz.gov to request a DDO application and more information about the DDO process.

7. (Comment) In order to confirm perimeter wall will not be placed within the street right-of-way, provide distance from the property line to the centerline of each adjacent street (S. Manitoba Av and E Victoria Dr). Show roadway surface, sidewalk, and setback from back of street curb to the property line.
See the street paving plan at https://maps-and-records.tucsonaz.gov/construction-plans/details/I-62-018. Scroll down and open the link to file “I-62-018_008” to see these dimensions.

Per this graphic, the distance from the property line to the back of street curb is 7’. The curb itself is 2’ wide. The distance from front of curb to street centerline is 16’. These measurements are for both streets.

If you have any questions about this transmittal, please contact Fernando L. Garcia at fernando.garcia2@tucsonaz.gov.
09/17/2024 PDSD Application Completeness Express REVIEW COMPLETED