Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0924-05179
Parcel: 127021930

Address:
5314 E 4TH ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-0924-05179
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/09/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/09/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-0924-05179 (5314 E 4TH ST TUCSON, AZ 85711)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC).

1. Note and specify all piping materials, P2609.
2. Provide the water pipe diameter between the meter and the shut off valve in compliance with P2903.7. A minimum 1” service pipe is required for supplying water to more than 9.5 fixture units. Show the size of the existing main water line.
3. Non-metallic water line requires a blue tracer line.
4. Minimum burial depth, 12”, P2603.5.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
09/09/2024 PDSD Application Completeness Express REVIEW COMPLETED