Permit Number: TC-RES-0924-05071
Parcel: 140253150

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0924-05071
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/21/2024 Site Engineering NOT REQUIRED
10/04/2024 Site Landscape NOT REQUIRED
10/21/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
09/26/2024 Residential Building REQUIRES RESUBMIT TC-RES-0924-05071
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings. Show the current code reference on the plans.

Provide a response letter on separate file with submitting the updated construction plan set.

GENERAL COMMENTS :

1. All plans submitted for a newly constructed one- or two-family dwelling after July 1, 2009 require a solar photo-voltaic system, or future installation preparation City of Tucson Ordinance #10549 . Show a minimum 300 SF clear solar-ready zone on a roof or framing plan, T103.3.

SITE PLAN:

1. Show the location of sewer HCS coordinated with Pima County Wastewater, R106.1.1. https://www.pima.gov/1766/Wastewater-Reclamation Update keynote #6 with the street sewer location.

PLANS:

1. Show the location of a minimum 22” x 30” attic access. Attic access is required for areas exceeding 30 SQ FT with a minimum of 30” of headroom and located in a hallway or readily accessible space, R807.1.

SECTIONS - DETAILS:

1. Eave ventilation is not appropriate with an unvented design without attic space, or rafter cavity space between insulation and roof sheathing, R806.1. Show solid eave blocking at detail #1 sheet 3.

MECHANICAL PLANS:

1. Provide the HVAC equipment capacity, M1302.1.
2. Provide demand calculations in accordance with Manual J/S/D standards, M1401.3, M1601.1. Systems shall be sized in accordance with Manual S based on building loads calculated in accordance with Manual J and duct systems sized in accordance with Manual D.

ELECTRICAL PLANS:

1. Show the Electric Vehicle receptacle circuit #26/28 with a 40-ampere breaker, N1104.2.1.

Please contact the plans reviewer if you have any questions:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
10/17/2024 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Fernando Garcia
Planning & Development Services Department – Zoning Review Section

PROJECT: TC-RES-0924-05071 – Residential Building – Addition/Alteration
5988 S Stewart Bl, Tucson, AZ 85706
Building Plan Review (1st Review)

TRANSMITTAL DATE: October 17, 2024

This site is located in the MH-1 zone (UDC 4.7.10). A single-family residence is permitted use in this zone (Table 4.8-2).

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised plans, as noted in the comment below, along with a detailed letter indicating responses to the review comments.

Alert me by email to fernando.garcia2@tucsonaz.gov upon resubmittal for faster review.

1. (Comment) Draw, dimension, and label property lines correctly. The dimensions along the southern lot line are labeled as 43’ 3”, 51’ 9”, and 25’ 0”. This adds up to 120’ total. Per the Pima County Assessor Parcel Map for this property, the southern property line is 115’. Dimensions for the other property lines are missing.

2. (Comment) Draw, dimension, and label the 16’ drainage and private sewer easement along the western boundary line as indicated on the final plat document for this property. The plat document is available at https://gis.pima.gov/maps/subdiv/select.cfm?null=&bkpg=64082&seqnum=20091760518

3. (Comment) Draw, dimension, and label the street half-right-of-way, to include the sidewalk, from S Stewart Bl. Reference paving plans can be located at https://maps-and-records.tucsonaz.gov/construction-plans/details/I-2010-017.

4. (Comment) Annotate height of building to top of roof on elevation drawings.

If you have any questions about this transmittal, please contact Fernando L. Garcia at fernando.garcia2@tucsonaz.gov.