Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0923-08281
Parcel: 132162320

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-0923-08281
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/07/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/07/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: Wyatt Berger
Lead Planner

PROJECT: TC-RES-0923-08281
4665 South Mountain Avenue – R-1
Additions (2nd Review)

TRANSMITTAL DATE: November 7, 2023

Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed.

The site is in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in the R-1 zone, subject to use-specific standards 4.9.7.B.5-.9.

1. This comment was not addressed. As the existing carport is being demolished, demonstrate that two motor vehicles can be parked on-site within the vehicular use area.

2. This comment was not addressed. Perimeter yards are based on a measurement from the design grade elevation to the highest point of the exterior building wall (UDC 6.4.5.B and Figure 6.4.5-A).

Per UDC Table 6.3-2.A, when a residential use is adjacent to a residential zone, the required interior setback is six feet or two-thirds the height of the exterior building wall, whichever is greater.

As measurements from the design grade elevation to the highest point of the exterior building wall were not provided, zoning cannot verify the required setbacks. Provide measurements from the design grade elevation to the highest point of the exterior building wall on the elevation drawings. Design Development Option (DDO) approval is required nonetheless to reduce the side perimeter yard setback to 3-8”. Contact Georgia.Pennington@tucsonaz.gov should you have questions about the DDO process.

If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951.
11/07/2023 Zoning Modifications - DDO REQUIRES RESUBMIT FROM: Georgia Pennington
DATE: 11/7/23

COMMENTS:

1. The submitted DDO application is incomplete. On the "Project Description and Applicant's DDO Request page," state the required and proposed setbacks, the reason(s) for the modification, and why the modification is compatible with the neighborhood.

2. Please verify the height of the structure on the site plan and make sure it matches the DDO application.

If you have questions about this transmittal, please contact me at georgia.pennington@tucsonaz.gov or 520-837-6311.
10/24/2023 PDSD Application Completeness Express REVIEW COMPLETED