| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/05/2023 | Site Engineering | NOT REQUIRED | |||
| 10/18/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/18/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-0923-08277 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. SITE PLAN: 1. Show the location and size of water pipe, R106.1.1. Each dwelling requires an appropriate source of water supply. Show the location and size of lines with connection points, R106.1.1. Identify the utility lines requiring upgrade or replacement. PLANS: 1. Notate a cool (white) roof finish as required by the ADU provisions. 2. Provide manufacturer’s calculations and data for pre-engineered trusses dated and wet-sealed by an engineer who is registered in Arizona, or notate the requirement for deferred submittal, R106.1. SECTIONS - DETAILS: 1. Show one-hour fire-resistive framed construction separating dwellings in compliance with IBC Table 721.1(2), R302.4. PLUMBING PLANS: 1. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show an appropriate yard pipe for supporting the existing and proposed dwellings and show an appropriate water meter size. 2. Show an individual accessible water supply shut off for the proposed dwelling unit, P2903.9.1. MECHANICAL PLANS: 1. Provide (an HVAC system with fresh air intake) whole-house mechanical ventilation with controlled exhaust, R303.4; N1103.6 & M1505.4. Show the minimum airflow rate setting and location of the device requiring this adjustable setting. A one bedroom dwelling under 1501 SF requires a 30 CFM continuous setting. 2. Provide demand calculations in accordance with Manual J/S/D standards, M1401.3, M1601.1. Systems shall be sized in accordance with Manual S based on building loads calculated in accordance with Manual J and duct systems sized in accordance with Manual D. OUTDOOR LIGHTING CODE 1. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. Update fixture “I”. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 10/18/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0923-08277 3015 East 1st Street – R-1 ADU (1st Review) TRANSMITTAL DATE: October 18, 2023 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. The site is in the R-1 zone (UDC 4.7.8). An accessory dwelling unit (ADU) is a permitted use in the R-1 zone, subject to use-specific standards 4.9.7.B.6, .8, and .9, and 6.6.3. 1. The legal description provided on the title sheet is incorrect and should be listed as “MUNDO VISTA S124.5’ LOT 9 EXC E19.5’ & E33’ S124.5’ LOT 8 BLK 1.” 2. According to the Property Record Card affiliated with the property, the dimensions of the property are 63.5 feet by 124.5 feet. Correct the depth of the property on the title sheet. 3. Provide a lot coverage calculation on the title sheet. Lot coverage includes the area of the property covered by buildings, outdoor storage areas, and vehicular use areas, whether paved or unpaved. Lot coverage shall not exceed 70% (UDC 6.3-2.A). 4. Review page eight of Paving Plan I-465 and provide dimensions from the centerline of 1st Street to the curb location, and from the curb location to the front street property line to ensure the front street perimeter yard is correctly depicted on the title sheet. The paving plan may be viewed here: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-465. 5. Per UDC 6.6.3.B.2, in addition to parking required for the principal use, one parking space shall be provided for the accessory dwelling unit. The parking requirement may be satisfied with available on-street parking or waived if the site is within ¼ mile walking distance of a transit stop or an enhanced bike route as listed in the Bike Boulevard Master Plan. Note the location of the two motor vehicle parking spaces required for the principal use and demonstrate compliance with UDC 6.6.3.B.2 on the title sheet. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 09/28/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |