Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-0923-08186
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/20/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/20/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-0923-08186 (6241 E 26TH ST TUCSON, AZ 85711) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1. The ¾” pipe on the 8’ segment from the meter to the Range intersection is undersized. 1" required per IRC Table G2413.4(1). 2. Provide a WP GFCI receptacle outlet on the same level within 25’ of all HVAC equipment, E3901.12. 3. Resubmit an updated gas pipe template and an updated floorplan/duct plan sheets showing these two corrections. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 09/20/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |