Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0923-08146
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/13/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/11/2023 | Residential Building | REQUIRES RESUBMIT | Provide a compliant roof framing plan with rafters sized with appropriate prescriptive load carrying capacity, R301.1 or provide an engineer’s sealed plan set for performance compliance consideration, R301.1.3. Rafters of 2x10 @ 24" OC are required for a 18' span Table R802.4.1(1). | ||
| 10/13/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-RES-0923-08146 7241 E. Irvington Rd. – R-2 Porch Addition (1st Review) TRANSMITTAL DATE: October 13, 2023 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. . 1. Perimeter yard setbacks for a porch structure are measured from the post supporting the roof structure (UDC 6.4.5.B.2), as long as the roof overhang does not exceed 2’-0” (UDC 6.4.5.D.1.b). Clearly show the post supporting the porch and provide a perimeter yard setback dimension from the post to the east property line on the plot plan. Also provide a roof overhang dimension on sheet 2. If the perimeter yard setback dimension is less than 6’-0” (UDC Table 6.3-2.A) a Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. 2. Based on aerial photos there is a fence/wall that shows up sometime after 2012. Zoning was not able to find approved compliance review documents for this fence/wall. Clearly show the fence/wall on the plot plan. 3. Remove the reference to “PUBLIC EASEMENT” from the plot plan as that area is part of the Irvington Rd. right-of-way, not an easement. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 09/21/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 09/22/2023 | Site Engineering | REVIEW COMPLETED |