Review Date Reviewer's Name Type of Review Description Status Comments
09/19/2023 Site Zoning APPROVED
10/02/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
10/02/2023 Residential Building REQUIRES RESUBMIT TC-RES-0923-08019

PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc.

SITE PLAN:

1. Show the water supply line bypassing the existing dwelling with connection directly to the existing water meter, R106.1.1.

PLANS:

1. Notate a cool (white) roof finish as required by the ADU provisions.
2. Locate door opening headers sized for the roof loading, IRC, R301.1. Detail the fastening of the load path structural components.

PLUMBING PLANS:

1. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show an appropriate yard pipe for supporting the existing and proposed dwellings and show an appropriate water meter size.
2. Show an individual accessible water supply shut off and water heater for the proposed dwelling unit, P2903.9.1.

MECHANICAL PLANS:

1. Show the current code reference at all notes.
2. Provide (an HVAC system with fresh air intake) whole-house mechanical ventilation with controlled exhaust, R303.4; N1103.6 & M1505.4. Show the airflow rate setting. A one bedroom dwelling under 1501 SF requires a 30 CFM continuous setting.

ELECTRICAL PLANS:

1. TEP may require a single service line to the building. Update the riser diagram showing a single meter with two distribution panels or a dual meter pack, E3403.

INTERNATIONAL ENERGY CONSERVATION CODE:

1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/pdsd
09/19/2023 PDSD Application Completeness REVIEW COMPLETED
09/20/2023 Site Engineering REVIEW COMPLETED
09/21/2023 Site Landscape REVIEW COMPLETED