Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0923-07991
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/26/2023 | Site Engineering | NOT REQUIRED | |||
10/09/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
10/02/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-0923-07991 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. Provide a clear and concise construction plan set. Sample plans are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits SITE PLAN: Provide a site plan showing the location of all buildings and utilities, R106.1.1. Show the location of the electrical service line to the building along with required service alterations. SECTIONS - DETAILS: 1. Provide a structure section showing existing and proposed features including a foundation, anchoring, framing, and roof sheathing R106.1. Include #4 rebar reinforced footing, R403.1 and with ½” x 8” bolts. 2. Clarify the beam size by updating the undersized 4x4 shown at detail #2. If you have any questions, please contact: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
10/09/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0823-07991 1546 W. Beantree Ln. - R-1 (RCP) Proch Addition (1st Review) TRANSMITTAL DATE: October 9, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9, & .11 1. Provide legal description, “STARR PASS HEIGHTS LOT 86 2. Based on aerial photos there are two (2) structures located in the rear yard that are not shown on the plan. Show these structures on the plot plan along with the height so that perimeter yard setback requirements can be determined. Provide perimeter yard setback dimensions from these structures to the applicable property lines. Minimum perimeter yard setback to interior property line is 3’-0”. As the square footage was not provided for these structures permit requirements cannot be determined. At a minimum zoning compliance is required. If the structures do not meet the minimum 3’-0” perimeter yard setback a neighbor’s setback waiver is required. To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s): My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ If a setback waiver is required to the north property line a signature from your HOA will be required. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
09/14/2023 | PDSD Application Completeness | REVIEW COMPLETED |