Permit Number: TC-RES-0923-07911
Parcel: 140390570

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SOLAR v.1

Permit Number - TC-RES-0923-07911
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/26/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/20/2023 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-0923-07911 (4760 E CONEFLOWER DR TUCSON, AZ 85756)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC).

1. For ground mounted systems, the Foundation must be engineered/designed, sealed and signed by an Arizona Registered engineer, to support the weight of the system and to resist the wind uplift, R106.1, R324.4.1.2.

2. Show grounding details for the mounting equipment and metal support frame, NEC 690.43.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
09/26/2023 Site Zoning REQUIRES RESUBMIT FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: TC-RES-0923-07911
4760 E CONEFLOWER DR Zoning R-1

TRANSMITTAL DATE:‎September 26, 2023


COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

1.COMMENT: Provide a Residential Plot Plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. This shall in include:
a. Lot coverage calculation that meets the requirements of UDC Article 6.4.3 & the example shown on the residential plot requirements. (Lot coverage must include vehicular use area whether improved or unimproved)
b. Zoning of adjacent parcels
c. All Utility lines
d. Property line distances

2.COMMENT: Draw dimension and label the height of the new structure measured from design grade to top of wall.

3.COMMENT: The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).



If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov
09/11/2023 PDSD Application Completeness Express REVIEW COMPLETED
09/15/2023 Site Engineering REVIEW COMPLETED