Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0923-07889
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/11/2023 | Site Engineering | NOT REQUIRED | |||
| 09/25/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/25/2023 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-0923-07889 (144 N MELROSE AV TUCSON, AZ 85745) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). Electrical Review: 1. Provide overhead electrical clearance above the new roof in compliance with E3604.2.1, 8’ min clearance above the new roof surface. The necessary mast height at the existing panel location may not be a feasible installation. Show a mast height necessary for achieving this 8’ clearance or relocate the service meter. Structural Review: 2. Show the required joist/rafter bearing contact to a wall or beam structure with foundation, R502.6 & R802.6. Replace the rafter connection to fascia or provide a registered Arizona engineer design analysis with sealed plan. See Sheet S-1 Section A, joist hangers attached to the fascia. 3. Show structural roof sheathing with edge fastening to (2x) structural framing members, Table R602.3 (1). Foundation Review: 4. Show the ABU66 post anchors with the required 5/8” anchor bolt, embedded a minimum of 7” into the foundation, R403.1.6. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 09/13/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0923-07889 144 North Melrose Avenue – R-2 Attached porch (1st Review) TRANSMITTAL DATE: September 13, 2023 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. 1. Remove the proposed porch from the lot coverage calculation as roofed areas, open on at least one side, which provide shelter to exterior areas, provided they are not used for utilities, maintenance, laundry, storage, or motor vehicle parking, are excluded from the lot coverage calculation (UDC 6.4.3.C.1.a). 2. T10CM01850 associated with the construction of the existing single-family residence is in “expired” status. Apply for a separate permit through the Tucson Development Center Online for the existing residence and provide the approved plan set. Reference former permit number T10CM01850 in the permit description and indicate that this is a “final-only” permit to call and complete all outstanding inspections. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 09/11/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |