Permit Number: TC-RES-0826-04856
Parcel: 133043260

Address:
1956 N RANCH DR

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SOLAR v.1

Permit Number - TC-RES-0826-04856
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/08/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/08/2026 Light Residential Building Review (OIP) - Standard REQUIRES RESUBMIT If you have questions regarding this Review, please contact Juan Quintana at juan.quintana@tucsonaz.gov
Please resubmit a comment response letter and corrected plan set addressing the following comments:
1) Provide a lag-bolt connection embedment depth demonstrating the wind load supporting capability, or provide an engineer’s calculation and sealed design, R301.1, R329.4.
2) Provide load calculations including the EV charger for the sub panel (Standard or Optional are accepted). Include all loads to be transferred in the calculation.
3) Clarify if Gateway and Combiner load panel are separate pieces of equipment.
4) EV charger must be GFCI-capable, alternatively provide a means of GFCI protection (including GFCI Overcurrent Protection Devices (OCPD)) 625.54
09/01/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Claire Leighou, Planner

PROJECT: TC-RES-0826-04856

1956 N RANCH DR

Roof Mounted Solar (1st Review)

TRANSMITTAL DATE: 8/31/26

Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed.

Comment 1: Please draw and label the two easements on this site. Per the subdivision plat map (linked below), there is a 20’ (10’ on each parcel) easement for drainage and sewer along the north property edge, and a 10’ pedestrian and utility easement along the west edge.

Plat map (Page 5, lot 76): https://onbase.pima.gov/publicaccess/DS_NextGen_Single/etc/cq/results.html?cqid=240&OBKey__552_1=33094

Comment 2: Please correct the site dimensions on the plan per the above linked plat map.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code

If you have any questions about this transmittal, please contact Claire Leighou at claire.leighou@tucsonaz.gov. Thank you!
08/28/2026 PDSD Application Completeness Express REVIEW COMPLETED