Permit Review Detail
Review Status: In Review
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0826-04833
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| N/A | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| N/A | Historic | PENDING ASSIGNMENT | |||
| N/A | Residential Engineering | PENDING ASSIGNMENT | |||
| 09/01/2026 | Addressing Validation | REQUIRES RESUBMIT | If you have questions regarding this review, please contact PDSD-Permits@tucsonaz.gov. Parcel/addressing issue. The site plan shows to be for anew dwelling. This location does not have units attached to the address. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to verify and add the units. After address/units have been added or verified you'll need to submit an address change request to update this record along with a new aerial/site plan that shows the corrected addressing. |
||
| 09/02/2026 | Residential Building | REQUIRES RESUBMIT | Please review the comments below and re submit. 1. Show the location and size of buildings, utility meters and gas, water, electric and sewer or septic lines from property line to building, R106.1.1. Identify the utility lines requiring upgrade or replacement. 2. Remove all references to the 2018 IRC and use the current legal 2024 IRC and ensure all references and calculations meet the 2024 IRC, I.E Attic venting, Energy values, GFCI, plumbing ect. 3. Show an individual accessible water supply shut off and water heater for the proposed dwelling unit, P2903.9.1. 4. E3606.5 Surge protection: all services supplying dwelling units shall be provided with a surge-protective device (SPD) installed in accordance with Sections E3606.5.1 through E3606.5.3. 5. Submit air leakage reports and truss package as deferred submittal. |
||
| 09/03/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston Planner PROJECT: TC-RES-0826-04833 740 S Osborne Av Tucson, AZ 85701 SFR (1st Review) TRANSMITTAL DATE: 09/02/2026 This site is located within the H0-3 Zone (UDC 4.7.12). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Please correct plans, as noted in the comments below, along with a Response Letter indicating how all Site Zoning comments were addressed. 1. Submit an application for a Historic Design Review. The materials submitted reference Historic Review SD-0726-00105 which are related to a commercial property. Since the subject property is located within the Barrio El Hoyo Historic District and contains a ‘Contributing’ structure, Historic review is required. Instructions for a Historic review may be found here: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Historic-Preservation . For further information, please contact PDSDHistoric@tucsonaz.gov . 2. Once the Historic packet has been approved, please: a. Submit the Historic approval letter b. Provide a site plan. The current plan set is missing the site plan. Please visit the following link to the Full site plan requirements (example included on page 3): https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Site-Plan-Examples c. Provide a landscape plan directly on the site plan. Requirements and examples are found here: https://middle-housing-cotgis.hub.arcgis.com/pages/Residential-Landscaping-Code d. Draw, dimension, and label (on the site plan) a 4’-wide accessible route from the driveway, sidewalk, or street to an accessible entrance. Per the City of Tucson Inclusive Home Ordinance 10463: all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Ensure the route meets accessibility standards as articulated in Sections 402-404 of the Accessibility Standards. See also TSM 7-01.4.3 for specifications, including the minimum 4ft-width, slope and permissible composition materials. e. Revised construction plans f. A comment response letter addressing all staff comments 3. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. For questions regarding Zoning comments, please contact me at: Roxanne.Johnston@tucsonaz.gov. |
||
| 09/01/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |