Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0826-04760
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/02/2026 | Residential Zoning | APPROVED | |||
| 09/10/2026 | Residential Engineering | NOT REQUIRED | |||
| 09/10/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/02/2026 | Residential Building - Standard | REQUIRES RESUBMIT | Please review the comments below and re submit. 1.Show the location and size of buildings, utility meters and gas, water, electric and sewer or septic lines from property line to building, R106.1.1 2.An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38 or R-30 when extended over the wall top plate for additions under 500 SF. Clarify the ceiling/roof insulation detail showing the air-impermeable rigid insulation material adhered to either side of the roof sheathing and the batt insulation in contact with the roof material. 3.Show a surge-protective device (SPD) as an integral part of or placed immediately adjacent to the service equipment, E3606.5. 4. Please provide a full panel schedule |
||
| 08/28/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |