Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0826-04760
Parcel: 110033560

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0826-04760
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/02/2026 Residential Zoning APPROVED
09/10/2026 Residential Engineering NOT REQUIRED
09/10/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/02/2026 Residential Building - Standard REQUIRES RESUBMIT Please review the comments below and re submit.
1.Show the location and size of buildings, utility meters and gas, water, electric and sewer or septic lines from property line to building, R106.1.1
2.An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38 or R-30 when extended over the wall top plate for additions under 500 SF. Clarify the ceiling/roof insulation detail showing the air-impermeable rigid insulation material adhered to either side of the roof sheathing and the batt insulation in contact with the roof material.
3.Show a surge-protective device (SPD) as an integral part of or placed immediately adjacent to the service equipment, E3606.5.
4. Please provide a full panel schedule
08/28/2026 PDSD Application Completeness Express REVIEW COMPLETED