Permit Number: TC-RES-0826-04669
Parcel: 141460580

Address:
9677 E HARKES DR

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.2

Permit Number - TC-RES-0826-04669
Review Name: RESIDENTIAL ADD/ALT v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/31/2026 Residential Zoning APPROVED
09/10/2026 Residential Engineering NOT REQUIRED
09/10/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/01/2026 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0826-04669
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review includes architectural, plumbing, mechanical, energy conservation and electrical compliance with the 2024 International Residential Code and 2024 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2024 code compliance.

Construction plans require minimum code compliance for approval. Provide plans showing the location and method or size of repair.

The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections.

Provide an Arizona engineer’s calculation, design, and seal for a performance design if the repair includes alteration of an engineered roof truss, IRC R301.1.

Provide a separate response letter addressing each comment with location of change on the plans.

Provide a clear and concise construction plan set. Sample drawings are available for understanding details. Sample plans at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits

PLANS:

1. Provide an Arizona registrant’s data for repair of an engineered trusses, R106.1.


ELECTRICAL PLANS:

1. Designate the circuit number at the location of each repaired light fixture, receptacle, appliance, and equipment disconnect switch, R106.1.1.
2. Interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors require combination type arc-fault circuit interrupters, E3902.16. Add notation to plans.
3. Provide GFCI protection for appliance receptacle outlets, E3902.12. Include:
1. Drinking water coolers
2. High pressure spray washing machines
3. Sump pumps
4. Dishwashers
5. Electric ranges
6. Wall-mounted ovens
7. Counter-mounted cooking units
8. Clothes dryers
9. Microwave ovens
10. HVAC equipment, E3902.14.

If you have any questions, please contact:
Kenneth.VanKarsen@tucsonaz.gov
City of Tucson Residential Building Safety
08/31/2026 PDSD Application Completeness Express REVIEW COMPLETED