Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-0826-04636
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/21/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/21/2026 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | If you have questions regarding this Review, please contact Juan Quintana at juan.quintana@tucsonaz.gov Please resubmit addressing the following comments: 1) Show adherence to Programmable Thermostat requirement for HVAC Installation controls based on 2024 IECC 403.1.1. Show the model number or manufacturer's specifications for the compliant device. 2) Provide HVAC equipment spec sheet including model numbers, capacities, and efficiency ratings for compliance verification 2024 IECC R403. 3) Equipment is oversized, proposed equipment has 137% of the cooling load and 180% of the heating load. Provide selection criteria based on Manual S criteria in accordance with M1401.3, 2024 IECC R403.7 |
||
| 08/20/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |