Permit Number: TC-RES-0826-04634
Parcel: 11803310C

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.3

Permit Number - TC-RES-0826-04634
Review Name: RESIDENTIAL SIMPLE REVIEW v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/02/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/02/2026 Restamp Residential Building REQUIRES RESUBMIT If you have questions regarding this Review, please contact Juan Quintana at juan.quintana@tucsonaz.gov
Please resubmit addressing the following comment:
1) The SPD provided Eaton BRPSURGE has a 3 kA nominal discharge rating, this device does not comply with the requirement in E3606.5 or 230.67 nor match PV4 nor PV5 equipment description. Please provide the spec sheet of the SPD to be install that is compliant, SPD must have a nominal discharge current rating not less than 10kA, be UL 1449, and be Type 1 or Type 2. 230.67
2) This permit is only for Unit 2 (existing Man. Home)
09/01/2026 Addressing Validation REVIEW COMPLETED
09/01/2026 PDSD Application Completeness Express REVIEW COMPLETED