Review Date Reviewer's Name Type of Review Description Status Comments
09/22/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/09/2026 Addressing Validation REQUIRES RESUBMIT If you have questions regarding this review, please contact PDSD-Permits@tucsonaz.gov.

Please include the full property address on all construction plan documents and resubmit after other reviews are complete. You cannot resubmit during an active review.

Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf
09/10/2026 Residential Building REQUIRES RESUBMIT TC-RES-0826-04553 2nd
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review includes architectural, plumbing, mechanical, energy conservation and electrical compliance with the 2024 International Residential Code and 2024 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2024 IRC with amendments and building ordinances for all dwellings.

Provide a separate response letter addressing each comment with location of change on the plans.

GENERAL COMMENTS:

1. Remove the clouding and delta notes from the plans which are in development status. The response letter is used for identifying review comment updates. Clouding should be used for revision submissions after the plans are approved and a permit is issued.
2. Plans submitted for a newly constructed one- or two-family dwelling after June 1, 2010, require gray water utilization or preparation, Ordinance #10579/11089 revised July 9, 2013. The ordinance revision now requires a gray drain line discharge from one fixture for a one-story dwelling. Show a bathing fixture drain looped 3’ beyond an exterior wall below grade before connection to the building drain when the clothes washer is not located at an exterior wall. Use the appropriate detail from the standard illustrations and remove the two-story options shown on sheet P-1.1 and update sheets P-1.0 and P2.0 (correct sheet number).

PLANS:

1. Individual dwelling units require separation with a 1-hour fire-resistance rated assembly without opening extended to the roof, R302.3. Update Section #1 on sheet A-4.0 showing a fire spread barrier between the ceiling and roof.

ELECTRICAL PLANS:

1. Show appropriate wire sizes for circuit #10/12, E3705.

INTERNATIONAL ENERGY CONSERVATION CODE:

1. Show occupancy sensors for all habitable spaces, IECC R404.2.

Please contact the plans reviewer if you have any questions:
Kenneth.VanKarsen@tucsonaz.gov
City of Tucson Residential Building Safety
09/22/2026 Residential Engineering REQUIRES RESUBMIT Permit: TC-RES-0826-04553
Project: Duplex
Location: 928 S BEAN AV
Review Date: 9/22/2026

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter review time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. Provide a response letter addressing each comment with location of change on the plans. Submit the separate response letter and plan set files.

1. Please remove the clouding and delta notes from the plans which are in development status. The response letter is used for identifying review comment updates. Clouding should be used for revision submissions after the plans are approved and a permit is issued.
2. Please add sheet numbers on the bottom right corner of the plan set “xx of xx”.
3. Please review and address Residential Building comments.

If you have any questions or concerns, please contact Joe Macaulay at: Joe.Macaulay@tucsonaz.gov
09/09/2026 PDSD Application Completeness Express REVIEW COMPLETED