Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.2
Permit Number - TC-RES-0826-04535
Review Name: RESIDENTIAL SIMPLE REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/17/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/17/2026 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | If you have questions regarding this Review, please contact Juan Quintana at juan.quintana@tucsonaz.gov Please resubmit addressing the following comment: 1) The SPD listed on the plans (Eaton BRNSURGE) is not code compliant with the nominal discharge current rating (In) requirement. SPD must be 10kA In per E3606.5.4 and 230.67 (E) |
||
| 08/17/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |