Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0826-04533
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/31/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/25/2026 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0826-04533 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review includes architectural, plumbing, mechanical, energy conservation and electrical compliance with the 2024 International Residential Code and 2024 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2024 code compliance. Provide a separate response letter addressing each comment with location of change on the plans. SITE PLAN: 1. Show the utility meters and lines from the utility source to the building, R106.1.1. Identify the utility lines requiring upgrade or replacement for supplying the demand of the proposed dwelling. PLANS: 1. Show the location of kitchen appliances at lot 93, R106.1.1. Clarify if the space includes alteration. ELECTRICAL PLANS: 1. The dwelling requires electrical supply from a single service, NEC 230.2 & IRC E3601.2. Clarify if the lot 93 service panel will be connected as a sub panel to the lot 92 service panel. 2. Interior alterations require the installation of smoke alarms in existing bedrooms, R310.2.2. Provide notation if the smoke alarms exist or are proposed. 3. Show receptacle outlets at altered spaces so that no wall point (exclude door openings) is more than 6’ from a receptacle outlet, E3901.2. 4. Show the location of the light wall switch at the altered bedroom entrance, E3903.3 If you have any questions, please contact: Kenneth.VanKarsen@tucsonaz.gov City of Tucson Residential Building Safety |
||
| 08/31/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit Activity Number: TC-RES-0826-04533 Project: Residential Addition/Alteration Location: 3321 E 2ND ST Review Date: 8/31/2026 Reviewer: Joe Macaulay – Civil Engineer - Residential Engineering Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter review time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. Provide a response letter addressing each comment with location of change on the plans. Submit the separate response letter and plan set files. Residential Engineering Review Comments: 1. A floodplain use (FPU) permit has been created for this residential addition/alteration permit, TE-FPU-0826-00351. The lot exists in a COT Flood Hazard Zone associated with Christmas Wash, and a floodplain use (FPU) permit with cost estimate is needed for all building permits. 2. Site engineering will be unable to approve permit TC-RES-0826-04533 until the associated FPU permit (TE-FPU-0826-00351) is approved. 3. Please review and address Zoning and Building comments. If you have any questions or concerns, please contact Joe Macaulay at Joe.Macaulay@tucsonaz.gov |
||
| 08/20/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Drew Szentesy Planner PROJECT: TC-RES-0826-04533 3321 E 2ND ST TUCSON, AZ 85716 Condo Combo (first review TRANSMITTAL DATE: 08/20/2026 This site is located within the R-3 Zone (UDC 4.7.12). A single-family attached residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6 & .12. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, Pima County Assessor’s Letter, and a response letter indicating how all Site Zoning comments were addressed. 1. Please upload the parcel combination approval letter from Pima County Assessor’s that was mentioned in the description. Please also include the updated legal description on the site plan if one was provided The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Drew.Szentesy@tucsonaz.gov |
||
| 08/19/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |