Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0826-04504
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/28/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/28/2026 | Residential Building - Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-RES-0826-04504 ADDRESS/PARCEL: (5837 E ROSEWOOD ST TUCSON, AZ 85711) Submit your revised reports along with a response letter which states how all Building Review Section comments were addressed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. Should you have any questions about these comments, I can be reached at ian.gillaspie@tucsonaz.gov. COMMENTS: 1. The rafter spacing of 32” O/C is beyond the prescriptive limits of IRC R802.4.1 (or R502.3.1) and R503.2.1.1. Provide rafter spacing and sheathing thickness that is in conformance with the above tables or provide an engineer’s stamped calculations. 2. Provide manufacturer specs showing section modulus and performance specs (span capability) for proposed microlam beam. (R106.1.1) 3. Please correct and resubmit. |
||
| 08/21/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Claire Leighou, Planner PROJECT: TC-RES-0826-04504 5837 E ROSEWOOD ST Porch (1st Review) TRANSMITTAL DATE: 8/21/26 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9. Comment: Thank you for submitting great plans! As the required setback for side yards is 5’ in this zone (UDC TABLE 6.3-2.A), a neighbor waiver will be needed to allow the reduced setback of 4’ on the west side of the property for the storage shed. Per UDC Article 6.6.2.D, an accessory structure that is detached from a principal structure shall comply with the setback standards of the principal structure, except that the accessory structure may be built to a parcel line with the consent of the adjacent property owner(s). To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s) (5831 E Rosewood St). My name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _______________________Date: ___________________________ The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code If you have any questions about this transmittal, please contact Claire Leighou at claire.leighou@tucsonaz.gov. Thank you! |
||
| 08/17/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |