11/18/2026 Residential Building REQUIRES RESUBMIT Please review the comments below and re submit.
1. The structure may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection for fire spread. Provide compliance with R302.1 (City of Tucson Amended) by protecting the structure placed within 3 feet of the property line in compliance with IBC Table 721.1(2). Include a one hour rated wall below the roof edge with foundation along the full length of structure near the property line or relocate the structure out of the fire separation distance. The DDO does not waive the need for fire rating.
2. Please provide 36 inches of working space from the face of the electrical panel.
3. Windows and openings can not be on a fire rated wall.


If you have any questions you can reach me at Zane.Aouane@tucsonaz.gov
11/18/2026 PDSD Application Completeness Express REVIEW COMPLETED