| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/26/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/26/2026 | Residential Engineering | REQUIRES RESUBMIT | Site Engineering Review TC-RES-0826-04436 136 E PLACITA ESTRELLA Date of Transmittal: 8/26/2026 Description: Construction of one new detached **8-foot × 16-foot (128 sq. ft.) gambrel-style storage shed** City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes Site Engineering comments are as follows: 1. The site plan provided does 10' drainage easement on West property line, 7' public utility easement (P.U.E) along the East, and the 6' building setback on the sides as described on the Subdivision Plat for ESTRELLA HEIGHTS (1-9), Book 56, Page 59. NOTE: the shed must remain out of the easement. https://onbase.pima.gov/publicaccess/DS_NextGen_Single/etc/cq/results.html?cqid=240&OBKey__552_1=56059 2. The site plan also does not match the lot layout nor the dimensions. The footprint of the primary structure is different from the provided site plan, as well. 3. The subdivision plat also requires a floodplain use permit (FPU) “prior to issuance of any building permit.” The required floodplain use permit, TE-FPU-0826-00343, has been generated on your behalf. 4. Additional comments may be forthcoming depending on the content of files submitted for subsequent review cycles. Our basic site plan can be found here for reference: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/plan-samples/basic-site-plan_feb2026.pdf *Please submit revised drawings along with a detailed response letter stating how each resubmittal comment has been addressed* To re-submit, visit the Tucson Development Center Online at: https://cityoftucsonaz-energovweb.tylerhost.net/apps/selfservice#/home Engineering Associate: Ryan Insalaco ryan.insalaco@tucsonaz.gov |
||
| 08/17/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Drew Szentesy Planner PROJECT: TC-RES-0826-04436 136 E PLACITA ESTRELLA TUCSON, AZ 85705 Shed, first review TRANSMITTAL DATE: 08/17/2026 This site is located within the R-2 Zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .8, & .9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 3. (Comment) The site plan you provided does not appear to match the site dimensions found in the City or County Plat Maps: https://gis.pima.gov/maps/subdiv/select.cfm?null=&bkpg=56059 Please update your property dimensions to update the shape and dimensions of the plat maps above. 4. Please include the name of the property owner on the site plan. 5. Please include the setbacks, dimensions, and heights of all existing structures including the rear-patio and existing shed on the southeast side of the property. Both will also need to be permitted for full site approval from zoning. 6. Please include lot coverage calculations by showing the following: a. Show square footage of the parcel b. Total square footage of all enclosed structures c. Total square footage of all vehicular use areas d. Add a lot coverage calculation, which is the percentage of the site occupied by enclosed buildings and vehicular-use areas Our basic site plan can be found here for reference: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/plan-samples/basic-site-plan_feb2026.pdf The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Drew.Szentesy@tucsonaz.gov |
||
| 08/13/2026 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 08/19/2026 | Residential Building - Standard | REVIEW COMPLETED | Under 200 Sqft |