Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.2
Permit Number - TC-RES-0826-04365
Review Name: RESIDENTIAL SIMPLE REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/10/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/10/2026 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | If you have questions regarding this request, please email PDSD-Permits@tucsonaz.gov 1) The ¾” main line pipe is undersized for the given length (65ft) and total appliance demand (172,000BTU). Size the pipe based on the length from the meter to the farthest attached appliance and max total Branch demand of all attached appliances using Table G2413.4(1) (Metallic Pipe). Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1. Please resubmit the gas pipe diagram showing a sufficient pipe size for the total demand. Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf |
||
| 08/10/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |