Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0826-04339
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/18/2026 | Residential Engineering | NOT REQUIRED | |||
| 08/13/2026 | Residential Zoning | NOT REQUIRED | Interior changes only, zoning not required. | ||
| 08/18/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/10/2026 | Addressing Validation | REQUIRES RESUBMIT | For questions, email PDSD-Permits@tucsonaz.gov. Please include the full property address on site plan and resubmit after other reviews are complete. You cannot resubmit during an active review. Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf |
||
| 08/10/2026 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0826-04339 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review includes architectural, plumbing, mechanical, energy conservation and electrical compliance with the 2024 International Residential Code and 2024 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2024 code compliance. Place sheet numbers on each page and the current reference code on sheet 1. Construction plans require minimum code compliance for approval. The submitted plans are not compliant and require alteration before approval. Provide a separate response letter addressing each comment with location of change on the plans. Provide a clear and concise construction plan set. Sample drawings are available for understanding details. Sample plans at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits FLOOR PLAN: 1. Show the location of the electrical service panel, R106.1.1. MECHANICAL PLANS: 1. Provide heating/cooling facilities in all habitable rooms, R325.8. (Mini split, extend duct from a central HVAC or an electrical base board heater) ELECTRICAL PLANS: 1. Designate the circuit number at the location of each proposed light fixture, receptacle, and appliance, R106.1.1. 2. Show receptacle outlets at wall spaces 2’ or more with no wall point (exclude door openings) more than 6’ from a receptacle outlet, E3901.2. 3. Show a wall switch controlled light at entrances or exits of the proposed habitable room, E3903.3. 4. New or extended interior 15A & 20A circuits serving receptacles, lights, and smoke detectors require combination type arc-fault circuit interrupters, E3902.16. Add notation to plans. If you have any questions, please contact: Kenneth.VanKarsen@tucsonaz.gov City of Tucson Residential Building Safety |
||
| 08/10/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |