Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0825-04232
Parcel: 124070020

Address:
939 E CADDIE ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0825-04232
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/22/2025 Residential Building - Standard APPROVED Requires current stamped truss plan set.
10/07/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
08/29/2025 Site Engineering - Standard REQUIRES RESUBMIT Permit: TC-RES-0825-04232
Location: 939 E CADDIE ST
Review Date: 8/29/2025
Site Engineering Comments:
1. This property lies within the High School Wash FEMA AE floodplain and will carry additional requirements.
2. An encroachment analysis and a grading plan will be required for this development. The grading plan must be submitted as a development package through TDC online, as an entirely separate submission. For the development package, provide the required hydrology study with encroachment analysis and grading plan. The grading plan should follow compliance with Technical Standards Manual 2-01 and Administrative Manual 2-06.0.0
3. The encroachment analysis will be required to describe how the proposed building and pads will or will not match existing condition and will determine impact to neighboring parcels. The analysis will review if the pad diverts flood water adversely, not increase BFE adversely, and not result in increased velocities/erosion potential adversely for other properties.
4. The grading plan is required due to development within a Floodplain. Tucson Code chapter 26, section 26-8.3.b and 26-8.d.2
5. A floodplain use permit will be required for this permit, please apply within the Sub-records of permit TC-RES-0825-04232
6. There may be further complications due to the existing/current LOMA status for the structure, which may require that a LOMA be filed.

If you have any questions or concerns, please contact
Marco Contreras
Marco.contreras@tucsonaz.gov
10/07/2025 Site Zoning - Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Fernando Garcia
Planning & Development Services Department – Zoning Review Section

PROJECT: TC-RES-0825-04232
939 E Caddie St
Tucson, AZ 85719

TRANSMITTAL DATE: October 7, 2025

This site is located in an NR-2 zone (UDC 4.7.9). A single-family residence is permitted in NR-2 subject to use-specific standards 4.9.7.B.6, .9, & .10

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:
Revised plans, as noted in the comment below, along with a detailed letter indicating responses to the review comments.

1. (COMMENT) This property is zoned NR-2 and is within the Rincon Heights-Pie Allen Neighborhood Preservation Zone (NPZ). Improvements within an NPZ are subject to design review and approval before Site Zoning can provide final approval.

See the instructions at the following link to submit for NPZ Design Review: https://www.tucsonaz.gov/files/sharedassets/public/v/3/pdsd/documents/planning-amp-zoning/npz-application-and-review-process-1.pdf

The Rincon Heights-Pie Allen NPZ Design Manual is available here: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/rincon-heights-pie-allen-npz-design-manual.pdf

For questions regarding this process, please reach out to Gabriel Sleighter at gabriel.sleighter@tucsonaz.gov.

2. (COMMENT) The existing structure to be demolished is over 50 years old, and as such, requires the submittal of two forms. Upload these completed forms as separate attachments to the permit in TDC Online. Please be aware that the structure to be demolished is a “Contributing Structure”. Reach out to the Arizona State Historic Preservation Office (SHPO) regarding any question about how its demolition may affect your property’s tax status: https://azstateparks.com/shpo

Historic Demolition Documentation: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/historic_demolition_application_form.pdf

Confirmation of Notice of Demolition: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/demolition_confirmation_statement2-14-14.pdf


3. (COMMENT) Clarify the perimeter yard dimensions table. The setback to the west where the property adjoins another R-2 lot is 6’, or 2/3 the height of the building, whichever is greater. To the east where the property adjoins an O-3 zone, the setback is 10’ or ¾ the height of building, whichever is greater.

4. (COMMENT) Per comments from the Site Engineering Reviewer, a grading plan will need to be submitted as part of a separate “Development Package” submittal before final Site Zoning approval for this permit can be provided.

5. (COMMENT) Further comments may be forthcoming on submittal of the full site plan.

If you have any questions about this transmittal, please contact Fernando L. Garcia at fernando.garcia2@tucsonaz.gov.
08/27/2025 PDSD Application Completeness Express REVIEW COMPLETED