Permit Number: TC-RES-0825-04150
Parcel: 121070520

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADU v.1

Permit Number - TC-RES-0825-04150
Review Name: RESIDENTIAL ADU v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/18/2025 Residential Building - Standard APPROVED
08/22/2025 Site Engineering - Standard NOT REQUIRED
09/22/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
08/22/2025 Addressing Validation REQUIRES RESUBMIT The address has unit numbers attached to it in our system. Please submit a change of address request through sub records to add unit numbers (Unit 2 for ADU) and also update the site plan to include unit numbers and resubmit the file. For help navigating sub records: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/withdraws-and-extensions.pdf
For questions: Building_Official@tucsonaz.gov
09/22/2025 Site Zoning - Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Jeffrey W. Cassidy, Planner
Planning & Development Services Department – Current Zoning Review Section

PROJECT: TC-RES-0825-04150 – Residential Building – New ADU
1318 N Sonoita Av Tucson, AZ 85712 (R-1 Zoning)
Site Plan Review – 1st Review

TRANSMITTAL DATE: September 22, 2025

This site is in the R-1 Residence Zone (UDC 4.7.8). An accessory dwelling unit is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .8, .9 and 6.6.3.

Plan review for the above referenced accessory dwelling unit has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:
The scope of this plan review covers zoning, use(s), legal description, adjacent properties, setbacks (building or wall heights), dimensional standards, property permitting history, density (units/lot size), and lot calculation (enclosed building and structure, parking, and driveway versus overall lot size) requirements. All code references are to the Tucson, AZ Unified Development Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PLANS AND ELEVATIONS OR DRAWING SET:

1. COMMENT: The site plan provided is incomplete.

a) Provide a site plan that meets the requirements show in the plot plan example at the following link:

https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example

More Specifically:

1) The plan graphic and scale noted are not in sync with another. Moreover, the reviewer couldn’t determine if the plan graphic is drawn to any scale. Provide a scalable drawing with the chosen scale and note accordingly.

2) Provide missing dimension from centerline of N Sonoita Av to curb.

3) Provide missing dimension from curb to property line.

2. COMMENT: Per the City of Tucson Inclusive Home Design Ordinance (https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf ), all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway (or apron), sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402-404 of the ADA Accessibility Standards (https://www.access-board.gov/ada/chapter/ch04/). See TSM 7-01.4.3 for specifications, including slope and composition materials.

3. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other the PDSD reviewer comments.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:
1. Corrected building permit
2. Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments.

To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home

Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf

If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code .
08/22/2025 PDSD Application Completeness Express REVIEW COMPLETED