Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.2
Permit Number - TC-RES-0825-04138
Review Name: RESIDENTIAL SIMPLE REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/21/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/21/2025 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | PDSD Residential Review Section PROJECT: TC-RES-0825-04138 Gas reconnect-(1st Review) (9032 E 31ST PL) TRANSMITTAL DATE: August 21th, 2025 Comments: 1. Pipe size for furnace and Range are under sized. And the 1” main line pipe is undersized for the given length and total appliance demand(200,000BTU). Size the pipe based on the length from the meter to the farthest attached appliance and max total Branch demand of all attached appliances using Table G2413.4(1) (Metallic Pipe). Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/gas_handout_2018_irc_2019.2.4.pdf Email questions to building_official@tucsonaz.gov |
||
| 08/21/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |