Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0825-04118
Parcel: 128031670

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-0825-04118
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/21/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
08/21/2025 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT PDSD Residential Review Section

PROJECT: TC-RES-0825-04118 installation of new gas line-(1st Review) (5721 E WHITTIER ST)
TRANSMITTAL DATE: August 21st, 2025

Comment: 1.The ¾” tankless water heater line pipe is undersized for the given length and total appliance demand (180,000 BTU). Size the pipe based on the length from the meter to the farthest attached appliance and max total Branch demand of all attached appliances using Table G2413.4(1) (Metallic Pipe) and resubmit a revised gas template showing the new water heater pipe size. Please see attached:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/gas_handout_2018_irc_2019.2.4.pdf
08/20/2025 PDSD Application Completeness Express REVIEW COMPLETED