| 08/21/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/21/2025 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | PDSD Residential Review Section PROJECT: TC-RES-0825-04118 installation of new gas line-(1st Review) (5721 E WHITTIER ST) TRANSMITTAL DATE: August 21st, 2025 Comment: 1.The ¾” tankless water heater line pipe is undersized for the given length and total appliance demand (180,000 BTU). Size the pipe based on the length from the meter to the farthest attached appliance and max total Branch demand of all attached appliances using Table G2413.4(1) (Metallic Pipe) and resubmit a revised gas template showing the new water heater pipe size. Please see attached: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/gas_handout_2018_irc_2019.2.4.pdf |
||