Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.3
Permit Number - TC-RES-0825-04101
Review Name: RESIDENTIAL ADD/ALT v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/10/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/10/2025 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston Planner PROJECT: TC-RES-0825-04101 5948 E 3rd St., Tucson, AZ 85711 Carport (3rd Review) TRANSMITTAL DATE: 11/10/2025 This site is located within the R-2 Zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Please correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. Comment 1 from the zoning review completed on 9/19/2025 requires a Design Development Option (DDO) for the attached carport encroaching 1’-6” into the required side 6’ perimeter setback. Our records indicate that DDO decision has not applied for. Without this decision, zoning approval cannot move forward. Please submit a DDO application under the Zoning Modification sub-record that has been created. For instructions on how wo apply for a sub-record, visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf For additional question regarding DDOs, contact Mark Castro at mark.castro@tcusonaz.gov 2. Zoning received the neighbor waivers for the shed, shade structure and ramada. Please either add the neighbor waiver information to the site plan – snip and paste to the site plan is acceptable, or add these to the DDO application request. 3. Comment 5 from the zoning review completed on 9/19/2025 has not been correctly addressed. The correct lot coverage would include only the residence, storage, and driveway/vehicle use area/carport. The pool, ramada and shade cover are not needed: Lot Size = 11,406 sf a. Residence = 2,256 sf b. Storage = 144 sf c. Vehicle Use = 1,299 sf (includes carport) Total = 3,699 sf (Lot Coverage) 3,699 sf ÷ (Lot Size) 11,406 = Total Lot Coverage 32% Please revise the site plan to show the correct lot coverage. 4. Comment 7 from the zoning review completed on 9/19/2025 has not been addressed. This comment read, “Indicate the setback dimension from the carport to the front street property line.” Please show this measurement on the site plan. The directions for measuring front perimeter setbacks for a cul-de-sac may be found in UDC 6.4.5.B.4. 5. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. For questions regarding Zoning comments, please contact me at: roxanne.Johnston@tucsonaz.gov |
||
| 11/04/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |