Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0825-04076
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/15/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/15/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0825-04076 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections. Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. Provide a clear and concise construction plan set. Sample drawings are available for understanding details. Sample plans at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits SITE PLAN: 1. Show the location of the electric service panel, R106.1.1. Identify the utility lines requiring upgrade or replacement. 2. Show the square footage of each proposed or altered addition, R106.1.1. PLANS: 1. Provide the structural drawings which are noted on sheet #6, R106.1. 2. Provide a closet Roof Framing Plan showing the beams and rafters sized for supporting live and dead structural loads (Table R802.4.1(1)) or provide an engineer’s sealed plan set for manufactured trusses, R301.1.3. SECTIONS - DETAILS: 1. Provide a wall section detail with (#4 rebar) reinforced 12” x 12” reinforced foundations for anchoring exterior framed (insulated) walls with pressure treated sills including ½” anchor bolts with 7” embedment, R403.1.6. 2. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground (R317.1 item 5). The weep screed may extend with a minimum clearance 4” above grade or 2” above paved areas, R703.7.2.1. 3. Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation, R806. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Identify the ventilation requirements and insulation types for complying with the condensation control issues. PLUMBING PLANS: 1. Show all drainage fixtures with connection to the public sewer system, P2602.1. 2. Show plumbing vents (VTR) within acceptable distances from traps, P3105.1. ELECTRICAL PLANS: 1. Designate the circuit number at the location of each light fixture, receptacle, appliance, and equipment disconnect switch, R106.1.1. 2. Show receptacle outlets at wall spaces 2’ or more with no wall point (exclude door openings) more than 6’ from a receptacle outlet, E3901.2. 3. Show the Bathroom receptacle with a separate 20 AMP dedicated circuit, E3703.4 and E3901.6. 4. Interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors require combination type arc-fault circuit interrupters, E3902.16. Add notation to plans. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Show compliance with the energy code requirements, N1102.1. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 09/05/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Claire Leighou Planner PROJECT: Case Number: TC-RES-0825-04076 Address: 727 N OLSEN AV Description: Adding a room in the location of the existing backyard deck and adding a closet to the master bedroom. (1st Review) TRANSMITTAL DATE: 9/05/25 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8.4) subject to Use Specific Standards 4.9.7.B.5 - 9. Based on the Pima County Assessor Record Map, the lot size is 48’ by 200’. Please update site plans to match both lot dimensions as well as square footage/lot size. Lot coverage should also be updated according to accurate site dimensions and lot size. Reference: https://www.asr.pima.gov/ParcelData/Map/Arm/MP03/03122.PDF The city code (UDC) requires a 20’ setback on residential properties between property line and front of structure. Please update and add front setback measurement. Minimum side setback per city code is 6’ or 2/3 the wall height (whichever is greater), not necessarily 7’. ‘Per city code’ markers for setbacks may be removed from plan. Site plan should include all existing structures on the property, and not just the subject property where changes are being made. Please update site plan and lot coverage calculations (primary concern is that garage is not shown on plan). Ensure to add setback measurements as well. Please re-label elevations with direction facing, rather than right/left. Front and rear may stay the same. Add wall height of new additions to elevations to ensure setbacks are meeting minimum requirements. Please also label new additions on elevations more clearly. Add note stating zoning of the property (R-1). Add label marking front street name (N Olsen Av). Add legal description of property. Can be found here: https://gis.pima.gov/maps/detail.cfm?&parcel=125060300 If you have any questions about this transmittal, please contact Claire Leighou at claire.leighou@tucsonaz.gov |
||
| 08/19/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |