Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.2
Permit Number - TC-RES-0825-04056
Review Name: RESIDENTIAL SIMPLE REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/20/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/20/2025 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | Review 1 Comments not addressed. Include pipe type/material. The 1/2" pipe to the furnace is undersized for the given length and appliance demand (100,000 BTU) using Table G2413.4(1) (Metallic Pipe). Any questions email building_official@tucsonaz.gov |
||
| 08/20/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |