Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0825-04041
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/28/2025 | Site Engineering - Standard | APPROVED | |||
| 09/17/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/10/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0825-04041 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. ELECTRICAL PLANS: 1. Interior alterations require the installation of smoke alarms in existing bedrooms, R314.2.2. Provide notation if the smoke alarms exist or are proposed. 2. Panelboards and overcurrent protection devices shall not be in clothes closets or in bathrooms, E3405.5. Relocate panel 3.03. 3. Show receptacle outlets at each kitchen counter space wider than 12” with no point along the wall line more than 24” from a receptacle outlet, E3901.4.1. Show receptacles within 2’ of counter edges or corners and no more than 4’ apart. 4. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services ---------------------- |
||
| 09/17/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Olga Salazar Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0825-04041 2230 E MONTE VISTA DR TUCSON, AZ 85719 Residential Alteration (1st Review) TRANSMITTAL DATE: 09/17/2025 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. Instructions for resubmittal: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf 01. COMMENT: Per subdivision plat map Book 12, Page 6, the west lot dimension is 140.68. Correct this dimension and the total lot area. 02. COMMENT: Draw, label and dimension all existing structures on site. 03. COMMENT: Draw and dimension all setbacks structures from each structure to each applicable property line. 04. COMMENT: Label the zoning (R-1) classification adjacent to the north and south boundary. 05. COMMENT: Provide the dimension from the centerline of East Monte Vista Drive to the face of curb, where asphalt meets the concrete curb (which is 25’ per paving plan I-622) and from face of curb to front street property line (which is 7’ per paving plan I-622). You can find this information on sheet 3 at the following link: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-622. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Olga.Salazar@tucsonaz.gov |
||
| 08/15/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |