Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0825-03950
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/12/2025 | Historic | NOT REQUIRED | |||
| 09/11/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/11/2025 | Residential Building - Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-RES-0825-03950 ADDRESS/PARCEL: (2301 E 7TH ST TUCSON, AZ 85719) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. Comments: 1. Show compliance with R310 providing egress from bedrooms with minimum net clear opening area of 5.7 SQ FT (5 SQ FT 1st floor). Also, show the minimum net clear opening dimension of 24” height and 20” width, and maximum sill height of 44”. 2. Show Bathroom receptacles with a separate 20 AMP dedicated circuit, E3703.4 and E3901.6. 3. Show locations of each smoke alarm on electrical plan (R314). |
||
| 09/10/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Erick Bieber Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0825-03950 2301 E 7th St, Tucson, AZ 85719 Residential Addition/Alteration (1st Review) TRANSMITTAL DATE: September 10th, 2025 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. Per Use Specific Standard 4.9.7.B.7, single family homes in the R-1 zone with 5 or more bedrooms require all parking spaces to be located on site, either in a side or rear perimeter yard. Demonstrate compliance with 4.9.7.B.7. 2. (Comment) Indicate the setback of the proposed addition from the south property line. 3. (Comment) Per UDC 6.4.5.C, the minimum front street setback is 20’. The indicated setback for the proposed addition appears to be less than 20’ from the south property line. A Design Development Option (DDO) will be required. Please submit a DDO application under the Zoning Modification sub-record that has been created. For instructions on how to apply for a sub-record, visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf For additional questions regarding DDOs, contact Mark Castro at Mark.Castro@tucsonaz.gov. 4. (Comment) Indicate the height of the exterior wall of the proposed addition. Provide height measurements from design grade to the top of the wall in accordance with UDC Section 6.4.5.B. 5. (Comment) Per UDC 6.4.5.C, the minimum side street setback is 10’. The indicated setback for the proposed addition is 7’ from the west property line. A Development Option (DDO) will be required. Please submit a DDO application under the Zoning Modification sub-record that has been created. For instructions on how to apply for a sub-record, visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf For additional questions regarding DDOs, contact Mark Castro at Mark.Castro@tucsonaz.gov. 6. Indicate both the length and the width of the parcel on the site plan. Only the width (140’), is indicated. 7. Clarify dimensions from the centerline of E 7th St to the face of curb, where asphalt meets the concrete curb (which is 19.6’ per paving plan I-420) and from face of curb to front street property line (which is 20’ per paving plan I-420). The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov |
||
| 08/12/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |