Permit Number: TC-RES-0825-03946
Parcel: 115023740

Address:
210 E ELM ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0825-03946
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/28/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
08/11/2025 Addressing Validation REQUIRES RESUBMIT This property has multiple units, so you will need to specify the unit the carport is attached to on the permit address by submitting an address change request in sub records. Here are some instructions for navigating sub-records: chrome-extension://efaidnbmnnnibpcajpcglclefindmkaj/https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/withdraws-and-extensions.pdf
Also please include the unit number on the address of the permit on the site plan documents and resubmit after other reviews are completed.
For questions building_official@tucsonaz.gov
08/28/2025 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0825-03946
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections.

Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files.

SITE PLAN:

1. Show the distance of the proposed structure from the side property line, R106.1.1.
2. All portions of the structure are required to be on the property with water runoff control.

PLANS:

1. The structure may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection for fire spread. Provide compliance with R302.1 (City of Tucson Amended) by protecting the structure placed within 3 feet of the property line in compliance with IBC Table 721.1(2). Include a one hour rated wall below the roof edge with foundation along the full length of structure near the property line or relocate the structure out of the fire separation distance. The roof may not extend beyond the fire spread barrier.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
----------------------
08/28/2025 Site Zoning - Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Erick Bieber
Planning & Development Services Department – Zoning Review Section

PROJECT: TC-RES-0825-03946
210 E Elm St, Tucson, AZ 85705
Residential Addition/Alteration (1st Review)

TRANSMITTAL DATE: August 28th, 2025

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone subject to use-specific standards 4.9.7.B.6, .9 and .10.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. (Comment) Clearly indicate the setback dimension of the proposed carport from the west property line.

2. (Comment) Per UDC Table 6.3-2.A, the minimum side and rear yard setbacks are 6’-0” or 2/3 the height of the exterior wall, whichever is greater. Based on the proposed carport with an approximate exterior column height of 7’8’, the required setback would be 6’-0”. The indicated setback for the proposed carport appears to be within the minimum setback of the west property line.

If the proposed carport is 1 foot or more away from the property line, a Design Development Option (DDO) will be required. Please submit a DDO application under the Zoning Modification sub-record that has been created. For instructions on how to apply for a sub-record, visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf
For additional questions regarding DDOs, contact Mark Castro at Mark.Castro@tucsonaz.gov.

If the proposed carport is less than one foot from the property line, a Board of Adjustment Variance would be necessary. More information about the B/A can be found at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Public-Meetings-Boards-Committees-Commissions/Board-of-Adjustment. If you are interested in exploring this option, please contact Mark Castro at mark.castro@tucsonaz.gov for more information.

3. (Comment) Clarify the height of the exterior column. Provide height measurements from design grade to where the beam meets the roof in accordance with UDC Section 6.4.5.B.

4. (Comment) Lot dimensions indicate the lot area is 7500sqft. Correct lot area figure under area calculations.

5. (Comment) The lot coverage calculation is not correct. Per UDC Article 6.4.3.C.1.a, roofed areas and porches that are open on at least one side are not included in the calculation. Remove porch square footage from lot coverage calculation.

6. (Comment) Provide setback dimensions of all existing structures, including covered porches, to all applicable property lines.

7. (Comment) Provide a dimension from the centerline of Elm St to the face of the curb, where asphalt meets the concrete curb (which is 17’ per paving plan) and from the face of the curb to the front street property line (which is 8’ per paving plan). The paving plan can be found at the following link: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-468

8. (Comment) Clarify intended directions of elevation plans. Both elevation plans indicate they are looking east.

9. (Comment) Correct the scale provided for the site plan. The measurements provided do not match the 1”=20’-0’ scale.

10. (Comment) Correct the parcel number under legal description.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code

For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov
08/11/2025 PDSD Application Completeness Express REVIEW COMPLETED