Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0825-03941
Parcel: 137070070

Address:
450 W MONTANA ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.2

Permit Number - TC-RES-0825-03941
Review Name: RESIDENTIAL SIMPLE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/13/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
08/13/2025 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT Permit Review TC-RES-0825-03941 (450 W MONTANA ST)
Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC).
 
1. Please clarify pipe size and pipe length to furnace. Please include meter location.

2. Please provide the pipe type based on the length from the meter to the farthest attached appliance and max total Branch demand of all attached appliances using Table G2413.4(1) (Metallic Pipe), Table G2413.4(7) (Polyethylene Plastic Pipe), or Manufacturer’s sizing requirements.
 
Contact with any questions: building_official@tucsonaz.gov
08/12/2025 PDSD Application Completeness Express REVIEW COMPLETED