Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.2
Permit Number - TC-RES-0825-03909
Review Name: RESIDENTIAL ADD/ALT v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/18/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/10/2026 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0825-03909 2nd PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections. The plans require details for each addition/alteration installed without a permit. Provide plans showing all changes after the last completed permit along with the proposed alterations. Provide a separate response letter addressing each comment with note of location of change on the plans. SITE PLAN: 1. Identify the location and square footage of structural additions/alternations, R106.1.1. Clarify the locations of replaced roofs. PLANS: 1. Provide details for each of the description items listed on sheet T1, R106.1.1. Include the second bathroom; new laundry room; replaced roof; heat pump; and 200 AMP panel. 2. Provide a Roof Framing Plan the beams sized for supporting live and dead structural loads, Table R602.7(3). Clarify the locations of replaced beams. 3. Remove the word “show” from the sill height notes on sheet A1 & A2, R106.1.1. This wording is a directive for the preparation of the plans. It is not appropriate to appear on the plans. ELECTRICAL PLANS: 1. Provide a One Line Diagram showing the feeder size for each sub panel, NEC 225.30 and E3403. Show all panels and panel schedules appearing on the plans. Sheet T1 has a 200 AMP panel and sheet E1 has a 100 AMP and a 60 AMP panel. If you have any questions, please contact: Kenneth.VanKarsen@tucsonaz.gov City of Tucson Residential Building Safety ---------------------- |
||
| 02/18/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston Planner PROJECT: TC-RES-0825-03909 2901 N Tyndall Av ., Tucson, AZ 85719 Renovations- Kitchen, Porches, Bath Additions (2nd Review) TRANSMITTAL DATE: 1/18/2026 This site is located within the R-2 Zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. Submit a response letter. A response letter was not included in this last submission addressing Site Zoning comments. 2. The site plan on Sheet T1 shows the unit addressed as ‘2903’ being located inside and outside of the lot lines. Please explain this in the next response letter. 3. On the site plan, clearly label where all proposed work was/is being done. Is any of the work expanding the existing footprint of the residence? Is the ‘old kitchen’ labeled on T1 to be converted into a covered porch as shown on Sheet A3? These sheets do not match. 4. If any demolition work is to occur, please show this on the site plan. 3. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov . |
||
| 02/09/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |