Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0825-03784
Parcel: 11703118A

Address:
41 W 2ND ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.2

Permit Number - TC-RES-0825-03784
Review Name: RESIDENTIAL ADD/ALT v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/18/2026 Residential Zoning APPROVED
06/23/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/23/2026 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0825-03784 2nd

PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings.

Each dwelling unit with kitchen requires a separate Pima County assigned street address after Zoning approval, R319. Show Pima County assigned unit numbers for the primary dwelling and Guest House on the site plan. https://www.pima.gov/1010/Addressing-Frequently-Asked-Questions

Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files.

SITE PLAN:

1. Show the Pima County assigned address on the site plan for each dwelling, R319.

PLANS:

1. Clarify keynote #204 on sheet a2.0. This is a required egress window, R310. Provide the opening size showing compliance with R310.2.1.

SECTIONS - DETAILS:

1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied to either side of the roof sheathing, R806.5. Fiberglass insulation may not be placed in contact with roof sheathing and vent openings are not appropriate without a continuous 1” air gap below the sheathing.

PLUMBING PLANS:

1. Provide the BTU demand of each appliance, total demand, and total developed length from meter to the most remote appliance on the system and verify the size of the supply pipe for the connected demand (may require upgrading), G2413.3 & Table G2413.4(1).

ELECTRICAL PLANS:

1. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3. Show circuit #1 on the plans.

If you have any questions, please contact:
Ken Van Karsen
Kenneth.VanKarsen@tucsonaz.gov
City of Tucson Residential Plan Review
06/09/2026 Addressing Validation REVIEW COMPLETED
06/09/2026 PDSD Application Completeness Express REVIEW COMPLETED