| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/30/2024 | Site Landscape | NOT REQUIRED | |||
| 09/30/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/05/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0824-05008 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. Provide a response letter on separate file with the updated construction plan set. Provide all sheets of the construction plan set in a single PDF file. SECTIONS - DETAILS: 1. Provide a reinforced post foundation sized for supporting the live and dead loads transferred to a soil bearing capacity of 1500 lbs/sf R401.4.1. The center post foundation of 12”x12” is undersized. 2. Show exterior footings at least 12” below the undisturbed ground surface, R403.1.4. Update the details on sheet A-04. OUTDOOR LIGHTING CODE 1. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. Replace the flood light with a shieled fixture which cannot illuminate horizontally. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services ---------------------- |
||
| 09/30/2024 | Site Engineering | REQUIRES RESUBMIT | TC-RES-0824-05008 1931 W PUEBLO VISTA BL 1. This project is within a regulated floodplain and requires a Floodplain Use Permit (FUP.) A cost estimate, as well as a copy of these plans will be required as part of the FUP submission. Please start a new FUP at our permit application web page: https://tdc-online.tucsonaz.gov/#/home Ryan Insalaco Engineering Associate City of Tucson Planning & Development Services Department Email: ryan.insalaco@tucsonaz.gov Phone: (520) 837-5351 |
||
| 09/26/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0824-05008 1931 West Pueblo Vista Boulevard – R-1 Carport addition (1st Review) TRANSMITTAL DATE: September 26, 2024 The site is in the R-1 zone (UDC 4.7.8). A single-family dwelling is a permitted use in the R-1 zone, subject to use-specific standards 4.9.7.B.5-.9. COMMENTS: 1. Combine all sheets into a single PDF flipped to the correct orientation. 2. Provide a site plan that meets the residential plot plan requirements found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf. The requirements are provided in both graphic and written formats. 3. The distance between the centerline of Pueblo Vista Boulevard and the edge of street location is incorrect. Per paving plan I-77-001, the distance between the centerline and edge of street is 15 feet: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-77-001. 4. A detached accessory structure appears in the front yard in Pima County Pictometry dated May 16, 2024. Per UDC 6.6.3.C, detached accessory buildings, including accessory dwelling units, are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line, except for shade structures or carports not over 400 square feet in floor area. Clarify whether this structure will remain. Further comments will be provided if this structure will remain. 5. A perimeter wall surrounding the property appears in aerial imagery in 2023. The approved drawings for T21CM09676 do not show a perimeter wall proposed. Show the perimeter wall on the site plan and notate the maximum height of the perimeter wall. Refer to UDC 6.6.2.I for specifics regarding the maximum height of a perimeter wall or fence. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised plan set as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf. |
||
| 08/28/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |