Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL FENCE/WALL v.3
Permit Number - TC-RES-0824-04988
Review Name: RESIDENTIAL FENCE/WALL v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/16/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/16/2025 | Residential Building | REQUIRES RESUBMIT | Section 1610.1.1 Presumptive active pressure: For typical unsaturated soils in Pima County, a presumptive active lateral pressure of 35 psf per foot of depth may be used without a geotechnical report for walls not exceeding 7 feet in height. Level backfill is assumed with this active pressure. Surcharges shall be applied as necessary. Per Tucson amendments stated above, Walls with a height greater than 7ft require an engineer's approval. The right side of the masonry wall exceeds 7ft, either obtain an engineer's stamp and approval of the plans or reduce the wall height to 7st. |
||
| 04/09/2025 | ROW Engineering Review | REQUIRES RESUBMIT | Existing fence/wall is encroaching in the public Right-of-Way (ROW), per paving plans, property line is 25' from Roadway center line on Astolat and 30' from roadway centerline on Lands End. See paving plans https://maps-and-records.tucsonaz.gov/construction-plans/details/I-834. Provide site plan showing correct property line location, Fence/wall should not encroach in the public ROW. |
||
| 04/07/2025 | Site Engineering | REQUIRES RESUBMIT | TC-RES-0824-04988 1801 W ASTOLAT RD Site engineering comments are as follows: 1. Please provide a site plan which shows the location of the proposed wall. It should be in accordance with the site plan example which may be found at this link: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example 2. Please show that the sight visibility requirements listed in TSM section 10-01.5.0 are being met. Ryan Insalaco – ryan.insalaco@tucsonaz.gov |
||
| 04/07/2025 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-RES-0824-04988 1801 W Astolat Rd Tucson, AZ 85713 Wall 7-8ft (1st Review) TRANSMITTAL DATE: 4/7/2025 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: Please provide a detailed site plan showing exactly where the proposed wall will be built. Please refer to the sample site plan if necessary: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf. If you plan on erecting a wall on the corner, please provide a sight visibility triangle on the site plan demonstrating the proposed wall will not interfere with traffic at the intersection of W. Astolat Road and S. Lands End Road. Per UDC 6.4.5.D.2.b, “On any corner lot, no fence, structure, object, or planting shall be erected or maintained to interfere with the sight visibility triangle provisions set forth in the Technical Manual”. 2. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 03/25/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |