Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-0824-04968
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/27/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/27/2024 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-0824-04968 (3241 E HAWTHORNE ST TUCSON, AZ 85716) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC). 1. Note and specify all piping materials, P2609. 2. Include pipe material type (ABS, PVC) in compliance with P3002.2 & P2005.4.2. 3. Show a cleanout at change of directions exceeding 45 degrees, P3005.2.4. 4. Show two-way cleanout only in the location specified in P3005.2.3. All other cleanouts shall be one-way in the direction of drainage flow, P3005.2.8. 5. Show the size of the existing sewer pipe that the new line is being tied into. The document is cutoff at the bottom and is missing this information. 6. Show the 3” ABS pipe’s (East side) connection to the main line on the South side. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 08/27/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |