Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0824-04946
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/25/2024 | Site Engineering | NOT REQUIRED | |||
| 09/27/2024 | Site Landscape | NOT REQUIRED | |||
| 09/27/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/29/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0824-04946 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. Provide a response letter on separate file with the updated construction plan set. Provide a clear and concise construction plan set. Sample drawings are available for understanding details. Sample plans at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits SITE PLAN: 1. Clearly show the location and size of proposed (new) rooms and the electrical service panel, R106.1.1. 2. Clarify if the TV room is existing or proposed. 3. Clarify the note “build a shower here”. Will that be an additional shower in the same bathroom layout with a sink, toilet and shower? PLANS: 1. Provide a floor plan of proposed rooms showing the location of all doors and windows, R301.1.3. Clearly show the location of all proposed foundations. 2. Provide a complete roof framing plan with headers and rafters sized with appropriate prescriptive load carrying capacity, R301.1. The rafter size must provide the space required for R-30 insulation including a minimum layer of R-5 rigid foam insulation. SECTIONS - DETAILS: 1. Provide a wall section detail with reinforced (#4 rebar) foundations for anchoring exterior framed walls with pressure treated sills including ½” anchor bolts with 7” embedment, R403.1.6. 2. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground (R317.1 item 5). The weep screed may extend with a minimum clearance 4” above grade or 2” above paved areas, R703.7.2.1. 3. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38 or R-30 when extended over the wall top plate for additions under 500 SF. Clarify the ceiling/roof insulation detail showing the air-impermeable rigid insulation material adhered to either side of the roof sheathing and the batt insulation in contact with the roof material. PLUMBING PLANS: 1. Show plumbing vents (VTR) within acceptable distances from traps, P3105.1. (1 ½”-6’, 2”-8’, 3”-12’). MECHANICAL PLANS: 1. Show bathroom (without a window) exhaust fan locations with minimum 50 CFM rating and duct to the exterior, R303.3 and M1505. ELECTRICAL PLANS: 1. Show Bathroom receptacles with a separate 20 AMP dedicated circuit, E3703.4 and E3901.6. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 09/23/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Fernando Garcia Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0824-04949 – Residential Building – Addition/Alteration 757 W Calle de Casas Lindas, Tucson, AZ 85756 Building Plan Review (1st Review) TRANSMITTAL DATE: September 23, 2024 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised plans, as noted in the comment below, along with a detailed letter indicating responses to the review comments. Alert me by email to fernando.garcia2@tucsonaz.gov upon resubmittal for faster review. 1. (Comment) The lot dimensions shown on the plan are 109’ x 69’. These are incorrect. Based upon the Pima County Assessor Record Map for this property, the correct dimensions are 102’ x 70’. This map can be viewed at the following link: https://www.asr.pima.gov/ParcelData/Map/Arm/MP09/M09089_B06.PDF 2. A second shed, or other structure, is visible in overhead imagery in the eastern corner of the lot. This is not depicted on the site plan. Please show this structure, its dimensions, and its setbacks. 3. Provide dimensions for the shed in the southwestern corner as well. 4. Please indicate height of both detached sheds. 5. No permits were found for the two detached sheds, which appears in overhead imagery about 2015. If these detached sheds are each below 200 sf and have no utilities going to them, they are permitted to be placed up to the lot line with a neighbor waiver per UDC Section 6.6.2.D. Two neighbor waivers would need to be provided – one each from the neighbor closest to each of the sheds. To provide the neighbor waiver, include the following statement on the next submittal, with the appropriate information filled in and the signature of the neighbors: My name is ______ and I am the owner of the property located at ______. I have reviewed the site plan and I have no objection to the structure being located or construct __ feet from the property line as depicted on the site plan. Signature: ________ Date: _________ If a neighbor waiver cannot be obtained, these sheds would have to meet setback requirements from the property line, which in an R-1 zoned lot are either 6 feet or 2/3 the height of the shed’s walls, whichever is greater. This can be reduced down to one foot with a Design Development Option (DDO). For more information about this option, contact Georgia Pennington at 520-837-6311 or georgia.pennington@tucsonaz.gov. UDC Section 1.4.1.C. requires a site to fully meet code compliance before any new permits can be issued. 6. Show the setback distance from the main house to the northern and southern property lines. 7. Show height of new building addition on the elevation drawing. If you have any questions about this transmittal, please contact Fernando L. Garcia at fernando.garcia2@tucsonaz.gov. |
||
| 08/26/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |