Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.6
Permit Number - TC-RES-0824-04932
Review Name: RESIDENTIAL NEW DWELLING v.6
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/29/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/29/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0824-04932 2771 W LEAWOOD DR. – R-1 Detached Shed (2nd Review) TRANSMITTAL DATE: April 29, 2025 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9. 1. This comment was not addressed correctly. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example. a. The plot plan shall be drawn at an engineering scale, i.e. 1” = 10’, 1” = 20’ and the scale will be clearly indicated on the plan. b. Provide a lot coverage calculation on the plot plan that meets the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements. c. Show all utility lines on the plot plan. d. Provide the zoning of this parcel and all adjacent parcels on the plot plan. e. Provide the legal description., “SADDLEWOOD RANCH LOT 217” on the plot plan. f. Provide perimeter yard setbacks that are readable. 2. This comment was not addressed. Depending on how the shed is orientated based on the 12’ height provided along with 8” block the minimum perimeter yard setback is 8’-4”. If the shed does not meet this setback a neighbors setback waiver, UDC Article 6.6.2.D, will be required. To secure this neighbor’s setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s): My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ If you are not able to secure this waiver a Design Development Option (DDO) to reduce the setback will need to be submitted and approved. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”. Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Provide the wall heights for the north and east wall so that perimeter yard setback requirements can be determined. The UDC can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 04/01/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |