| 09/30/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/30/2025 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston Planner PROJECT: TC-RES-0824-04920 2175 S Avenida Planeta Freestanding Carport (1st Review) TRANSMITTAL DATE: 09/29/2025 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. A list of zoning review items are provided at this link: 1. Please correct the address of the subject property as it is incomplete. 2. The distance between the proposed detached carport and the front porch. 3. Either rotate the subject property on the plot plan or change the North Arrow as the direction is currently incorrect. 4. Add the street names to the plot plan. 5. Provide elevation diagrams for the detached carport. 6. Fully dimension the lot. To find these dimensions, please visit https://www.asr.pima.gov/ParcelData/Map/Arm/MP13/M13016_B49B.PDF 7. The zoning north of the subject property is R-1, not R-2. Please relabel to R-1. 8. Draw the vehicle use area(s) within the lot and label the proposed carport. 9. The lot itself measures .18 of an acre (8,012 sq ft). Under the Lot Coverage Calculation section on the plot plan, please correct the following: a. The lot coverage shown on the plot plan. b. The square footage for the area(s) for vehicular usage. c. Recalculate the lot coverage as it is not the lot size, but rather the enclosed structures and vehicular use areas. d. Divide the lot coverage by lot area and show this calculation on the site plan. 10. Draw and label a dimension from the centerline of the W. Avenida Planeta to the edge of pavement or curb (approx. 16’) and a dimension from edge of pavement or curb to the property line (approx. 14’) per Terra Del Sol paving plans I-748J: http://maps-and-records.tucsonaz.gov/construction-plans/details/I-748J . 11. Include and label the half of the right of way width (25’) for the W. Avenida Planeta cul de sac located south of the subject property. 12. For further information regarding plot plan directions, please visit https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example . Additionally, the Unified Development Code can be found at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code 13. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov . |
||
| 09/11/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |